Merge intelligently
Use whole-universe HTP, LTP or port-priority behavior, or build a deliberate output from consecutive blocks and individual channel assignments.
- Custom Block
- Custom Channel Map
- B or C Priority
- HTP / LTP
DMX SYSTEMS / MERGE + SPLIT + TEST
Merge two DMX controllers into one receiving chain. Split one controller across two chains. Or put a known test signal on any selected port.

| Port | Merge | Split |
|---|---|---|
| A | Output | Input |
| B + C | Inputs | Outputs |
THE FIELD PROBLEM
SuperMUX is a wired DMX tool first. Its three ports reverse direction with the selected operating mode, so the same installed hardware can combine sources, distribute a universe or become a controlled test source.
TRY SUPERMUX
Drag the sliders to change DMX levels. Compare merge strategies, route an input to different outputs, or run a moving test pattern.
Browser simulation: custom merge maps support all 512 addresses, with eight outputs shown at a time. Other merge strategies and split preview channel 1; test previews eight channels. No hardware is connected. Device timing and signal-loss detection are not simulated.
Choose a source address, then move B or C below. Every output mapped to that source follows it.
B + C → PORT A · CHANNEL 1
/ 255
HTP takes the higher level: C wins.
Enter each source range and where it starts on Port A, then apply both blocks. Overlapping destinations are rejected.
Example: B 1–4 to A 1–4; C 1–4 to A 5–8.
Block and individual assignments share this map. Change a row’s source, then press Apply. One source can feed several output channels; OFF sends zero.
| A output | Take from | Source channel | Assignment | DMX level |
|---|
Move the input level and watch the selected receiving chains respond.
PORT A → B + C
Both receiving chains follow the input.
GENERATOR → PORT A
Press Run test pattern to start.
Each column is a DMX channel. Its height and brightness follow the generated value.
WHAT IT ACTUALLY DOES
Use whole-universe HTP, LTP or port-priority behavior, or build a deliberate output from consecutive blocks and individual channel assignments.
Send one input to both outputs, route ranges to separate receiving chains or build a custom per-channel map for each output.
Disconnect external transmitters and generate a known signal on one selected port for commissioning and troubleshooting.
LOCAL WEB INTERFACE
Join the SuperMUX hotspot and open the embedded interface, or reach the unit on a compatible 2.4 GHz building network. The DMX Engineering app can discover the unit, open the same controls and handle supported firmware updates.


INSTALL + COMMISSION + OPERATE
The current guide covers wiring, every merge and split workflow, the test generator, Wi-Fi setup, persistence and commissioning checks.